Wholesale Led Power Supply 12v - LED Emergency Driver Lasting 3 Hours – SASELUX
Wholesale Led Power Supply 12v - LED Emergency Driver Lasting 3 Hours – SASELUX Detail:
- This emergency kit provides
60-180 Minutes duration in the event of a power failure. Suit for LED luminaire with external driver 100W or below.
- Lithium iron phosphate Battery backup
IFR18650MUB 3.2V 1500mAh battery cell,
- Output: DC10-50V. 50-200V Constant power 2-6W
Dimension
-Automatic self-test function
-Status of the battery.
-Status of the LED
-Charge condition
-Duration test
-Functional test
Application
-LED Downlight, Tri-proof, Linear LED light fixture
Battery pack
There are three combinations of batteries. Please ask the service commissioner for the specifications.
Model |
Output Constant power |
Battery backup |
Duration |
CK-7091L | DC 10-50V 6W |
LiFePO4 6.4V 1.5AH |
1 hour |
CK-7091H | DC 50-200V 6W |
LiFePO4 6.4V 1.5AH |
1 hour |
CK-7092L | DC 10-50V 3W |
LiFePO4 6.4V 1.5AH |
2 hours |
CK-7092H | DC 50-200V 3W |
LiFePO4 6.4V 1.5AH |
2 hours |
CK-7093L | DC 10-50V 4W |
LiFePO4 6.4V 1.5AH |
1.5 hours |
CK-7093H | DC 50-200V 4W |
LiFePO4 6.4V 1.5AH |
1.5 hours |
CK-7094L | DC 10-50V 2W |
LiFePO4 6.4V 1.5AH |
3 hours |
CK-7094H | DC 50-200V 2W |
LiFePO4 6.4V 1.5AH |
3 hours |
CK-7095L | DC 10-50V 4W |
LiFePO4 6.4V 3.0AH |
3 hours |
CK-7095H | DC 50-200V 4W |
LiFePO4 6.4V 3.0AH |
3 hours |
Automatic self-test function
LED status display
Functional test
Connecting battery firstly, connecting mains supply then, this emergency conversion module will automatically go into emergency mode and discharge for 3 seconds.
Timer stats to calculate when battery is fully charged for the very first time.
The emergency conversion module will automatically discharge 10 seconds every 30 days as a short time functional test.
Duration test
Emergency conversion module will automatically discharge 90 minutes every 180 days.
If a mains supply failure occurs at any time, before or during functional test and duration test period, emergency conversion module will go into emergency mode immediately. Timer would not re-calculate if battery is not disconnected after emergency mode. If the battery is disconnected, timer will re-calculate.
The test switch and indicator light are connected through a plug on the inverter.
Product detail pictures:
Related Product Guide:
Dedicated to strict quality management and thoughtful client services, our experienced staff customers are generally available to discuss your demands and guarantee full client pleasure for Wholesale Led Power Supply 12v - LED Emergency Driver Lasting 3 Hours – SASELUX , The product will supply to all over the world, such as: Costa rica, Netherlands, Detroit, We attained ISO9001 which provides solid foundation for our further development. Persisting in "High quality, Prompt Delivery, Competitive Price", we have established long-term cooperation with clients from both overseas and domestically and get new and old clients' high comments. It is our great honor to meet your demands. We are sincerely expecting your attention.